Overview

The advancement of electrical power systems has been reflected in the developments in power transformer manufacturing. This has led to a wide range of power transformers. Their ratings range from a few kVA to several hundred MVA and are used for a wide variety of applications. Power transformer protection varies with the application and transformer importance. In the case of a fault within the power transformer it is important to minimize tripping time in order to decrease the impact of thermal stress and electro-dynamic forces. Distribution power transformers can be protected by using fuses or overcurrent protection relays. This leads to time-delayed protection due to downstream co-ordination requirements. Nevertheless, time delayed short circuit clearance is unacceptable on larger power transformers due to system operation/stability and cost of repair. This course is suitable for electrical engineers with a desire to understand the power transformers protection fundamentals. Presented details include details related to interturn, tank and core faults. Information on over-voltages, magnetizing inrush, overheating is also included. Upon successful completion engineers will be able to address the most important power transformer protection aspects, widely adopted protection schemes and arrangements and their proper application.

The advancement of electrical power systems has been reflected in the developments in power transformer manufacturing. This has led to a wide range of power transformers. Their ratings range from a few kVA to several hundred MVA and are used for a wide variety of applications. Power transformer protection varies with the application and transformer importance. In the case of a fault within the power transformer it is important to minimize tripping time in order to decrease the impact of thermal stress and electro-dynamic forces. Distribution power transformers can be protected by using fuses or overcurrent protection relays. This leads to time-delayed protection due to downstream co-ordination requirements. Nevertheless, time delayed short circuit clearance is unacceptable on larger power transformers due to system operation/stability and cost of repair. This course is suitable for electrical engineers with a desire to understand the power transformers protection fundamentals. Presented details include details related to interturn, tank and core faults. Information on over-voltages, magnetizing inrush, overheating is also included. Upon successful completion engineers will be able to address the most important power transformer protection aspects, widely adopted protection schemes and arrangements and their proper application.


More Information
Learning Objectives

Learning Objectives

This continuing education course is intended to provide you with the following specific knowledge and skills:

  • Power transformer fault background
  • Power transformer differential protection
  • Power transformer restricted earth fault and overcurrent protection
  • Phase correction and filtering of zero sequence currents
  • Overfluxing and tank-earth protection
  • Buchholz protection
  • Earthing transformer protection
  • Autotransformer protection
  • Non unit and unit protection schemes
  • Power transformer condition monitoring
Contact Hours10 Horas
CIAPR coursesCURSO TECHNICO
InstructorVelimir
DevicesDesktop, Tablet, Mobile
LanguageEnglish

IACET ACCREDITED PROVIDER

IACET

Self Learning Solutions LLC es una empresa con más de 14 años de experiencia en este mercado. En Self Learning Solutions estamos orgullosos de haber obtenido la acreditación IACET para nuestra organización, junto con las aprobaciones necesarias para comercializar nuestros productos en todo Estados Unidos. Self Learning Solutions está acreditado por la Asociación Internacional para la Educación y Formación Continua (IACET). Self Learning Solutions cumple con el estándar ANSI / IACET, que es reconocido internacionalmente como un estándar de excelencia en las prácticas de instrucción. Como resultado de esta acreditación, Self Learning Solutions está acreditada para emitir la CEU IACET.
Esto significa que nuestros clientes pueden confiar en que nuestros cursos serán aprobados por los consejos estatales.  

Check our IACET accreditation

 

SLSTECH System Requirements

To run our system effectively you should, as a minimum, use the system components listed on this page. If you do not, the system may still work but some functionality may be lost. Workplace IT environments' internal configurations can also restrict the functionality of our system. Access to content may be affected, as may the possibility of uploading files. File size limitations may also apply. Workplaces may also have older versions of software, and our system may not perform well with these.

Operating system

  • Recommended: Windows 7, 10, Mac OSX Sierra, iPad IOS10

Internet speed

  • Use a broadband connection (256 Kbit/sec or faster—this will ensure that you can view videos and online presentations) through USB wireless modem, ADSL, T1/T2, fibre optic or cable.

  • Dial-up access will be significantly slower, and we do not recommend it for using our system.

Internet browsers

    Compatible browsers include:

  • Google Chrome 32 bit version 50 or later (recommended for optimal compatibility, this has been thoroughly tested on Windows)

    Safari 10 or later (recommended for optimal compatibility, this has been thoroughly tested on Mac)

    Note that add-ons and toolbars can affect any browser's performance.

  • MS Internet Explorer is not recommended

Settings

    We recommend that the following be enabled:

  • Cookies

  • Pop-ups (in both Internet browser and security software)

  • Javascript

  • We recommend that you use the latest version of Adobe Flash Player.

Software

  • We recommend that you use the latest version of Adobe Acrobat Reader.

  • To view all the resources uploaded to Hazmat Authority, you will probably need to have Microsoft Office (Word, Excel, PowerPoint) or an equivalent (e.g. Open Office, Viewer) installed.

Security

    With all firewalls, ensure that you enable uploading of files.